Digital Lux Meters HTC Model KM-LUX-99 - KM-LUX-100K - KM-LUX-200K
Digital Lux meter KM 99 100 200 / HTC lux Meters
www.total-automation.in FEATURES
Display in Lux
Precise & easy readout.
High accuracy in measuring
Data Hold & Light Sensor
LSI circuit use provides high reliability & durability
Auto zero Adjustment
Photo Detector : One silicon photodiode with filter.
Permits a wide range of light measurements.
Low Battery Indication
Compact, light weight, & excellent operation
LCD display can clearly read out even in High Ambient Light
Separate LIGHT SENSOR allows user take measurements at an optimum position
ELECTRICAL SPECIFICATIONS :
MODELS-KM-LUX-99
Display- 3½ digit,18mm(0.7”) LCD
Range- 0-2,000 / 20,000 / 50,000 Lux
Resolution -1 / 10 / 100 Lux
Accuracy- ± (5% rdg + 2 dgts)
Over-range-Indication of “I”
Sampling Time-0.4 second
Sampling Frequency-0.2 times / sec
Operating Temperature-0 to 50 Deg C. (32 -122 Deg F)
Operating Humidity-Less than 80% R.H.
Repeat-ability-± 2%
Temperature Characteristic-± 0.1% / Deg C
Peak Hold-No
Display In Foot Candle (fc)- No
Angle deviation from
cosine characteristics-No
Data logging-No
USB interface-No
Power Supply-DC 9V Battery Consumption current approx. 2mA
Dimension-118(L) x 70(W) x 29(H)mm
Weight-Approx. 200g
MODELS-KM-LUX-100
Display- 3½ digit,LCD
Range- 0-2,000 / 20,000 / 1,00,000 Lux
Resolution-1 Lux
Accuracy-<=10,000 Lux : ± 4%rdg ± 0.5 f.s.
> =10,000 Lux : ± 5%rdg ± 10 digits
Over-range-Indication of “I”
Sampling Time-0.4 second
Sampling Frequency-0.2 times / sec
Operating Temperature--10C to 40 DegC. (32F~104 DegF)
Operating Humidity-Less than 70% R.H.
Repeatability-± 2%
Temperature Characteristic-± 0.1% / Deg C
Peak Hold-No
Display In Foot Candle (fc)-No
Angle deviation from
cosine characteristics-No
Data logging-No
USB interface-No
Power Supply-DC 9V Battery Consumption current approx. 2mA
Dimension-230(L) x 72(W) x 30(H)mm
Weight- Approx. 190g
MODELS-KM-LUX-200
Display- 3½ digit,18mm(0.7”) LCD
Range- 0-200 / 2,000 / 20,000 / 2,00,000 Lux, 0-20/200/2,000/20,000 FC
Resolution-0.1 Lux
Accuracy-<20,000 Lux : ± 3%rdg ± 0.5 f.s.
> 20,000 Lux :± 5%rdg ± 10dgts
Over-range-Indication of “I”
Sampling Time-0.4 second
Sampling Frequency-0.4 times / sec
Operating Temperature-0 C to 40 DegC.(32F~104 DegF)
Operating Humidity-Less than 80% R.H.
Repeatability-± 2%
Temperature Characteristic-± 0.1% / Deg C
Peak Hold-Yes
Display In Foot Candle (fc)-Yes
Angle deviation from
cosine characteristics-No
Data logging-No
USB interface-No
Power Supply-DC 9V Battery Consumption current approx. 2
Dimension-149(L) x 71(W) x 41(H)mm
Weight-Approx. 250g
ACCESSORIES :Instruction Manual, Carrying Case, Battery