Power board issue make the system reboot
The access equipment Huawei MA5616 was reported faulty
because this equipment reboot in randomly way, this issue affects the services, the reboots happen in order than two times everyday. This is why, the customer report this behavior like a Critical because the subscribers lose the service provided.
Huawei DSLAM Version; MA5616V800R306C01B053
04-21 02:16:22 The slot number which board plug in when it reboot:0
The reason of rebooting :Board have been pulled out or no power
TAMBILLO(config)#display alarm history alarmlevel critical list
{ <cr>||<K> }:
Command:
display alarm history alarmlevel critical list
------------------------------------------------------------------------
AlarmSN Date&Time Alarm Name/Para
------------------------------------------------------------------------
89 2012-03-05 02:22:41 The LOS occurs on the Ethernet optical
port
FrameID: 0, SlotID: 0, PortID: 0
75 2012-03-04 02:17:11 The LOS occurs on the Ethernet optical
port
FrameID: 0, SlotID: 0, PortID: 0
65 2012-03-03 02:14:39 The LOS occurs on the Ethernet optical
port
FrameID: 0, SlotID: 0, PortID: 0
43 2012-03-02 02:06:37 The LOS occurs on the Ethernet optical
port
FrameID: 0, SlotID: 0, PortID: 0
35 2012-02-29 03:34:05 The LOS occurs on the Ethernet optical
port
FrameID: 0, SlotID: 0, PortID: 0
------------------------------------------------------------------------
ALARM 24 FAULT MAJOR 0x02310000 EQUIPMENT 2012-04-17 02:18:01-05:00
ALARM NAME : The communication between the board and the control board
fails
SRVEFF : SA
PARAMETERS : FrameID: 0, SlotID: 4, Board Name: H835ADLE
DESCRIPTION : The communication of the board interrupted ,the services in
the board fail
CAUSE : The communication with the control board is abnormal
ADVICE : (1)There is no need to deal with it if the operation for
resetting the board or loading software is performed (2)Check
whether the board is in position, If yes, reset the board, If
not, insert the board again(3)Reload the board software
--- END
Huawei CCUB Main Control Board
ALARM 6 FAULT CRITICAL 0x0a31a0e2 EQUIPMENT 2000-01-02 15:44:18-05:00
ALARM NAME : The LOS occurs on the Ethernet optical port
SRVEFF : SA
PARAMETERS : FrameID: 0, SlotID: 0, PortID: 0
DESCRIPTION : The LOS occurs on the Ethernet optical port
CAUSE : The optical path is faulty
ADVICE : 1.Check whether the optical fiber is properly connected If
not, re-connect it 2.Replace the optical fiber
--- END
The problem is located in the power system, because the controller board was change and the issue still happen after the replacement, the procedure is determinate the manufacturing date of PDIA to know id is neccesary a urgent maintenance.
TAMBILLO(diagnose)%%display elabel 0/5
[Board Properties]
BoardType=H831PDIA
BarCode=020CKS6T9B602675
Item=03020CKS
Description=MA5616,H831PDIA,DC Power Input Unit,1*1
Manufactured=2009-11-26
VendorName=Huawei
IssueNumber=00
CLEICode=
BOM=
with this information about the manufacturing date is 11-26-2009, R&D recommend two procedures 1- replacement of the board. 2- Rectifier the board
The most easly and quickly way to solve this problem was the replacement, so the PDIA board was changed and the problem not ocur again
Possible causes:
-The Controller board is faulty and make this issue happen
-The power supply ont the equipment is faulty
-The PDIA board is faulty and is neccessary replace it (Sulfurization of the Switch on the panel of PDIA Power)
When the PDIA DC power board operates in a corrosive gas environment without protection, the switch on the panel of the board is sulfurized and consequently the impedance of the switch becomes great. As a result, the switch fails and the device is powered off.
The maintenance of PDIA board is very important to avoid this kind of issue happen, about the rectification the next lines give a complete guide to perform this corrective action.
Rectification measure:
The problem can be rectified when the switch on the panel is turned on and off multiple times. After the board operates for a long period of time (two to three months), however, the similar problem will occur again.
Workaround:
The problem can be thoroughly resolved after the affected board is replaced with a PDIA power board manufactured after February 28 of 2010. Replacing the affected board with a board manufactured on or before February 28 of 2010 can only resolve the problem in a short period.
Solutions:
1. For the new devices to be delivered
An EC request was already sent to the production department on February 28 of 2010 for changing the BOM of the PDIA power board. The new power board is designed not to provide a switch. Therefore, the repeated reset problem that occurred on the original boards will not occur on the new boards.
2. For the devices used on the existing networks
Huawei performs rectification measures, that is, removes the PDIA power board and inserts a short-circuiter to the switch socket, to thoroughly resolve the problem.
Disposal of replaced material
00001. Materials used for rectification: Short-circuiters and panel surface mounting sheets, which will be sent to each representative office by post and then distributed to the personnel responsible for carrying out the rectification project.
00002. Materials not used after rectification: Switch cables, which are recommended to be scrapped locally.
Rectification Scope and Completion Date
The rectification scope is the entire network, and the required completion date is December 31, 2010.
Rectification Guide
Step 1: Save the data configurations of the target device.
Step 2: Power off the device, and then remove the -48 V power cable connected to the panel of the PDIA power board.
Step 3: Remove the PDIA power board, remove the switch socket, and then take out the switch from the panel.
Step 4: Insert the short-circuiter to the switch socket, and then mount the square-shaped surface mounting sheet on the panel.
Step 5: Insert the PDIA power board into the device, power on the device with -48 V power, and then start the device. The services are restored after the device is started.
Step 6: After rectification, fill in the Quality Inspection Report of Rectification of the H831PDIA Power Boardand send it to the Chinese region coordinator for the record.
Huawei MA5616 Silver Line
Repeated Ring on SIP Client due to MxU system parameter setting in MA5620 when NOTIFY is received on the SIP CLIENT
How to modify a GPON UNI Port?
How to Set the Layer2 Isolation Status Parameters?