Are You Searching For Low Current System In Dubai? Look no further than the Low Current System from Green Energy Options. This system is designed to help you reduce your energy consumption by low current system.
Low-current systems have various applications across different industries due to their reliability, efficiency, and cost-effectiveness. Thes
High Voltage, Low Current Power Supply (2000VDC from 15VDC)
High Voltage, Low Current Power Supply (2000VDC from 15VDC)
This is a high voltage, low current power supply capable to deliver 2000VDC output from 15VDC input voltage. It uses the combination of simple step-up transformer and Cockroft-Walton voltage multiplier circuit. Power supply with very high output voltage is a very useful source that can be effectively used in many applications like biasing of gas-discharge tubes and radiation detectors, etc. Such…
View On WordPress
IPTV System Commissioning
Verify the physical connectivity by checking LEDs in the servers. All LED should be linking
Check if all equipment installed can be seen
Connect to devices in the assigned VLAN at MDF and at IDF level to verify connectivity
Connect to devices in the room in assigned VLAN to test the connectivity.
Use Video LAN software to test multicasting across network
Check all the channels are present to the…
View On WordPress
Fans Commissioning
Mechanical:
Check and ensure the shipping bolts/clamps are removed.
Check tightness of all nut/bolts, screws, fasteners etc.as applicable.
Check the alignment of belt and adjust the tension (where applicable)
Check the duct work connections are complete as per approved drawings/details.
Ensure the fan interior and the ducts are cleans and free from foreign material.
Properly secure all safety…
View On WordPress
CCTV Commissioning
Visually inspect camera and equipment.
Determine whether installation is complete.
Determine whether cabling and equipment is mechanically secure.
Perform all hardware and software pre-commissioning tasks.
Pre-Commissioning Hardware Inspection:
All IP CCTV cameras have been installed at the locations specified in the design documentation.
Electrical & communications cables have been appropriately…
View On WordPress
Battery Rack installation:
Clean the area free from dust and other particles to install the Rack.
Install the Battery rack with proper supports as per the approved UPS room layout.
Ensure that the correct battery cabinets are installed adjacent to the each UPS.
Batteries:
Position the batteries as per the supplier’s recommendation.
Clean the batteries.
Terminate the batteries with battery link as…
View On WordPress
Structured Cabling Commissioning
Check if the complete link products are in place such as outlets, cable, patch panel, labeling and termination of the link
Once it is confirmed that the physical link is in place, the following parameters have to be tested to confirm compliance to the required Cat 6 specification. Parameters to be tested are:
Length
Propagation Delay
Impedance
Resistance
Capacitance
Attenuation
Near end cross…