Vascular intervention
seen from United States
seen from China
seen from United States
seen from China
seen from United States
seen from Australia

seen from Germany

seen from United States

seen from United States

seen from Germany

seen from Belarus
seen from Malaysia

seen from United States
seen from United Kingdom
seen from United States

seen from Australia

seen from United States
seen from United States

seen from Kenya

seen from Malaysia
Vascular intervention
Myval | Transcatheter Aortic Valve Replacement (TAVR) for Aortic Stenosis | Meril Vascular Intervention
Myval
Balloon expandable TAVR system with bovine pericardium tri-leaflet valve on a Nickel Cobalt alloy frame with Hybrid-Honey comb design.
The unique hybrid design of Myval, post crimping, has a unique appearance of alternating light and dark bands under fluoroscence, supporting ease of positioning on the annular plane.
Unique crimping pattern with MyvalTM, due to the geometry of design ensures precise orthotopic device placement without any deep throating into the LVOT.
Precise annular placement ensures that there is no conduction system disturbances thus eliminating need for a new pace maker as seen with previous technologies.
MyvalTM comes with a Navigator Balloon with a Dual-Stopper System for precision in positioning & deployment.
Benefits
01
NAVIGATOR BALLOON DUAL-STOPPER SYSTEM FOR PRECISE DEPLOYMENT FOR PRECISE DEPLOYMENT
02
UNIQUE BANDING PATTERN UNDER FLUORO FOR GUIDED PRECISION PLACEMENT
03
UNPRECEDENTED HYBRID HONEYCOMB DESIGN FOR INTUITIVE PRECISION & Orthotopic placement
For detailed information on Myval product, please click here
www.myval.com
Nautica | Intracoronary Shunts for Bypass Surgery | Heart Valves | Meril Vascular Intervention
Nautica - Intracoronary Shunts for Bypass Surgery, Heart Valves & Meril Vascular Intervention
Intracoronary Shunts
The NAUTICATM Intracoronary Shunt is specially designed to provide a bloodless operative field during vessel anastomosis procedure . The simple yet effective design temporarily allows the blood flow towards distal bypass route from anastomosis site in the vessel. The NAUTICATM Intracoronary Shunt facilitates anastomosis during Coronary Artery Bypass Grafting & Beating Heart Surgery. NAUTICATM Intracoronary Shunt is a radiopaque one piece device consisting of flexible silicon hollow shaft having bulb shaped tip.The radiopaque tag indicates diameter of the bulb & is attached to the shunt via suture. The NAUTICATM Intracoronary Shunt is safe and easy for insertion & is removed from the vessel just prior to the completion of anastomosis.
Benefits
01 Vessel Occlusion, Stenting & Distal Perfusion.
02 Specially designed for better visualization at the site of anastomosis.
03 Soft Silicon Bulb Tip - Easy Atraumatic Insertion & Removal.
04 Broad Bulb Tip Ends - Secures with the arterial wall & builds a bloodless operative field.
For more detail visit our website - https://www.merillife.com
BioMime Morph | Drug Eluting Stents for Cardiac Arrest | Meril Vascular Intervention
BioMime Morph - Drug Eluting Stents for Cardiac Arrest & Meril Vascular Intervention
Proven benefits of BioMime, now available as a tapered stent system. Treat long diffused lesions with a single stent – one and done.
Long diffused lesions are typically treated through multiple overlapping stents, which are associated with higher rate of restenosis/ revascularization.
Biomime MorphTM tapers as per vessel anatomy, it helps avoid multiple stent placement thus reducing the probability of fracture and restenosis.
Biomime MorphTM is a Sirolimus Eluting Coronary Stent System with an ultra-thin 65 µm strut thickness. This next generation SES has a Novel Hybrid Design with closed cells (on both ends of the stent) & open cells (in the middle) - this allows for Morphology Mediated Expansion for adequate conformability and lesser edge dissections.
BioPoly Biodegradable Polymer: 2µm low thickness, stable and elastic polymer
Stent design with non-linear S links & Y connectors allows for high flexibility and adequate side branch access.
Strut width variability ensures optimal radial strength.
Benefits
01
Avoids overlapping and associated restenosis and revascularization.
02
Tapers as per vessel anatomy.
03
Reduces procedural time as single stent is deployed.
For more detail visit our website - https://www.merillife.com
BioMime Branch | Drug Eluting Stents for heart attacks post Hypertension | Meril Vascular Intervention
BioMime Branch - Drug Eluting Stents for heart attacks post Hypertension & Meril Vascular Intervention
Proven benefits of BioMime, now available a dedicated bifurcation stent system. An intuitive design for treating bifurcations lesions.
Treating Bifurcation lesions with multiple stents can be a long and complex procedure.
Biomime BranchTM is a Sirolimus Eluting Coronary Stent System with an ultra-thin 65 µm strut thickness. This next generation SES has a Novel Hybrid Design with a Proximal Main Branch anchoring segment and a Distal tapered Side Branch segment. The two segments are joined through an advanced “Flexi Connector Technology” for continuous access and protection of side branch. The design offers ease of implantation and complete main vessel stent integration.
Due to the Step-Up Ballon System: The main branch and side branch segments get deployed at one go which reduces the overall procedural time and complexity of multiple hardware usage.
Post branch deployment, the main branch segment can be stented as a regular stent procedure.
Benefits
01
It saves overall procedural time as compared to bifurcation stenting using multiple DES.
02
BioMime Branch limits multiple layering of stent struts in carina.
03For more detail visit our website- https://www.merillife.com
It also provides optimal main branch and side branch scaffolding and coverage.
MeRes100 | Bioresorbable Vascular Scaffold (BVS) for angioplasty| Meril Vascular Intervention
MeRes100
MeRes100TM is a bioresorbable vascular scaffold system that resorbs naturally in the artery within a period of 2-3 years thus leaving the vessel in its true form and nature.
The complete resorption prevents chance of late clinical events like restenosis. Thus, also reducing likelihood of repeat revascularization versus metallic DES.
MeRes100 is a 2nd generation bioresorbable technology with low strut thickness of 100microns leading to lower crossing profile for ease of delivery and early endothelialization.
Couplets of tri-axial RO markers on both ends for enhanced visibility and large size matrix covers multitude of morphologies and lesions.
Benefits
Next Generation BioResorbable Scaffold: World's first 100µm BVS
Ideal strut thickness to minimize vascular injury & ensure early endothelialization
Virtual Tubing: Couplets of tri-axial RO markers at either end of the scaffold
Visit our website to learn more about the product.
BioMime Lineage | Drug Eluting Stents (DES) for Surgery after Cardiac Arrest | Meril Vascular Intervention
BioMime Lineage
BioMime Lineage is a Sirolimus Eluting Coronary Stent System with an ultra-thin 65 µm strut thickness on a Lineage Delivery System with Monolithic Design. Monolithic Distal Shaft Design has the best-in-class acute performance, pushability and trackability due to:
Reinforced inner lumen material to facilitate high pressure stent deployment without any risk of inner lumen shrinkage.
Elongated distal tip of 7.5mm ensures lower entry profile and high success for device crossing in complex anatomies.
Advanced balloon material used for distal shaft, to reduce its elongation.
Hydrophilic coating on entire distal shaft except balloon for increased lubrication and ease of navigation.
Robust, skived hypo tube to have a better force transmission from proximal to distal end to avoid kinking and lesion crossing difficulties.
BioMime LineageTM the proven BioMime stent: Novel Hybrid Design with closed and open cells that allows for Morphology Mediated Expansion.
BioMime family of Drug Eluting Stents are available in 94 countries; >500,000 stents deployed .
BioMime Lineage is a Sirolimus Eluting Coronary Stent System with an ultra-thin 65 µm strut thickness on a Lineage Delivery System with Monolithic Design. Monolithic Distal Shaft Design has the best-in-class acute performance, pushability and trackability due to:
Reinforced inner lumen material to facilitate high pressure stent deployment without any risk of inner lumen shrinkage.
Elongated distal tip of 7.5mm ensures lower entry profile and high success for device crossing in complex anatomies.
Advanced balloon material used for distal shaft, to reduce its elongation.
Hydrophilic coating on entire distal shaft except balloon for increased lubrication and ease of navigation.
Robust, skived hypo tube to have a better force transmission from proximal to distal end to avoid kinking and lesion crossing difficulties.
BioMime LineageTM the proven BioMime stent: Novel Hybrid Design with closed and open cells that allows for Morphology Mediated Expansion.
BioMime family of DES are available in 94 countries; >500,000 stents deployed .
Visit our website to learn more about the product.