Basic Boiler Calculations | Feed water Flow | Blow Down | Make Up | Condensate
Basic Boiler Calculations Feedwater = Make up + Condensate Return Feedwater Flow (FWF) = Steam Make + Blowdown(BD) Feedwater Flow (FWF) = Steam Make + Steam Make Cycles -1 Blowdown = Steam make Cycle-1 or = FWF Cycles % Blowdown = as a % of FWF Cycles Condensate Return is also expressed as % of FWF If Condensate Return = 60% Make up = 40% % Condensate + % Make up = 100% = FWF As the boiler…