Учёт тепла тела человека в пассивном доме. #пассивныйдом #расчеттеплопотерь #теплопритоки #теплопоступления #phpp #phpp9 #теплопассивногодома https://www.instagram.com/p/CMmX70kFZXs/?igshid=1tj790avtp1jw
How you get passive house certification
You want to get passive house certification, but you don't know exactly what you need to do. Here you fint all you need to meet the strict Passive House certification criteria.
In this moment there are more than 30 Passive House accredited Certifiers in the world. Why you need a Passive House Certification? The certification provides an important and visible form of quality assurance. The first criteria: the Heating Energy Need is not to exceed 15 kWh per square meter of net living space (dealt with flooring location) each year or 10 W per square meter peak demand. In climates where active cooling is needed, the Area Cooling Energy Demand requirement roughly matches the heat need requirements above, with an additional allowance for dehumidification. The second criteria: the Renewable Main Energy Need (PER, inning accordance with PHI technique), the overall energy to be used for all domestic applications (heating, hot water and domestic electricity) should not exceed 60 kWh per square meter of treated floor area each year for Passive Home Classic. Three: In regards to Airtightness, an optimum of 0.6 air modifications per hour at 50 Pascals pressure (ACH50), as validated with an onsite pressure test (in both pressurized and depressurized states). Four. Thermal comfort should be fulfilled for all living locations throughout winter along with in summertime, with not more than 10 % of the hours in a given year over 25 ° C. For a complete introduction of general quality requirements (soft criteria) see Passipedia.
The Passive House is the world's prominent standard for energy-efficient building and construction; the savings in heating costs are generally over 80 % in contrast with the national statutory requirements for brand-new constructions. The heating demand is less than 15 kWh/(m ² a) in the Passive House, based upon the "heated/cooled functional area" (TFA, roughly: the living area). The approach for developing a Passive Home for a specific building job and a specific environment is explained in typically available literature-- the tools needed for this, like the PHPP for example, are available on the market. There are numerous Qualified Passive House Components available-- for main European environment zones along with for other environments. Based on the requirements for Passive Homes, there are also requirements for older structures. Read the full article
#Passivhaus Fact Sheet 16 – #PHPP Hitting Airtightness Requirements
#Passivhaus Fact Sheet 16 – #PHPP Hitting Airtightness Requirements
This Fact Sheet (below) focusses on Airtightness and it’s relevance in PHPP
Fact Sheet No. 16 – PHPP ‘ Airtightness – Hitting the target’ – Click to download pdf (907Kb)
View On WordPress
#Passivhaus Fact Sheet 15 – #PHPP Hitting Primary Energy Requirements
#Passivhaus Fact Sheet 15 – #PHPP Hitting Primary Energy Requirements
This Fact Sheet on ‘Hitting Primary Energy Requirements in PHPP’ was harder to write than that on Space Heating Demand as there’s a lot of variables concerning frequency of use and energy consumption figures; I have however tried to keep it to the single sheet (in line with all the other FACT SHEETS in the FACT SHEETSsection and also to provide information for those new to Passivhaus as well as…
View On WordPress
Fact Sheet No.14 - PHPP Hitting Space Heating Demand for #Passivhaus
Fact Sheet No.14 – PHPP Hitting Space Heating Demand for #Passivhaus
This new Fact Sheet (also in FACT SHEETS section of website) gives a few methods of hitting (and bettering) the Passivhaus Space Heating Demand requirements. It focusses on alternative strategies that may not be obvious in addition to improving u-values, airtightness etc…
Fact Sheet No. 14 – PHPP ‘Hitting the target (1-5)’ – Click to download pdf (341Kb)
There will be additional Fact sheets…
View On WordPress
Enjoying teamwork with Fergus @comfortforyou on #Passivhaus in Mayo
Enjoying teamwork with Fergus @comfortforyou on #Passivhaus in Mayo
I’m currently working alongside Fergus (Certified Passivhaus Consultant) at Comfort Solutions providing Passivhaus consultancy on a new house in Mayo.
I’m not the architect on this one but we’re providing Passivhaus/PHPP modelling together on a new one-off house in Mayo (more details at later stage).
Below is where we’re currently at:
Looking good so far. Any comments welcome.
If you’d like…
View On WordPress
Final Air Test and Pre-Certification Assessment.
We carried out our final air test on the 24th October and achieved 0.4 air changes per hour at 50 Pascals exceeding Passivhaus Requirements! This figure has been inputted into our pre-construction assessment by Warm and we are achieving a heating energy demand result of just 18kWh/m2yr which is well within the Passivhaus Enerphit requirements (25kWh/m2yr).