🦾 The dual scan protocol 🦾 one very popular approach when acquiring data for treatment plan of fully Edentulous. - make sure the prosthesis or teeth try in is approved by the patient and the VDO is correct. - intimate fit of the intaglio surface is mandatory, temporary reline with a light body PVS can improve that. - radiographic markers or fiduciary should be spread out ( minimal 3, 6 are recommended) - the prosthesis is scanned with the same settings but on a piece of low density foam. - be careful when placing the prosthesis in the patients mouth to minimize possible displacement of the markers. I hope that helps and please share your tips or questions. #digitaldentistry #digitaldentures #implantdentistry #ufcid (at University of Florida Center for Implant Dentistry) https://www.instagram.com/p/CDjM3nTF3ED/?igshid=qf6ga9reeuw3